XGN -12
FLN -12
X G N - 1 2 Series SF6 Insulated Ring-main Unit
F L N - 1 2Series SF6 Insulated Load-switchXGN -
F L N -
XGN -12 SF6 XGN -12 Series SF6 Insulated Ring-main unit,acombination of foreign ad-
vanced technology and domestic power-supply demand, is designed and
manufactured by Jiangsu Changjiang Electric Co. Ltd. Certified by integrated
inspection and long-term trial operation, its performance has detinitely entirely
IEC298 GB3906 3~35kV reached standards of IEC298 AC Enclosed Metal Switching Equipment
and GB3906 3~35 kV AC Metal Enclosed Switchgear Equipment , and its
IP4X protective grade is up to the standard of IP4X .Characterized by its small size,
easy handling and convenient maintenance, the Ring-type Network Switchgear
has become a new unember of Middle-voltage products widely used in
construction of urban and rural electric network.1
-12
Type and Designation
2
-12
Operational Conditions
3
Main Characteristics
4
Technical Data of switchgear
5
Outline Dimensions
6
Construction
7
FLN -12 SF6
FLN -12 Series SF6 Insulated Load-switch
8
Primary schemes
9
Installation1
Type and Designation
X G N -12
box-type Rated short-time withstand current
Fixed
Rated current
Indoor
No. of Design (kV) Rated voltage
2
Operational Conditions
: +40 -25 Ambient temperature:+40 to -25 .
: 1000m Maximum site altitude:1000m max.
: 95 ; Relative humidity:daily average less than 95%,
90 monthly average less than 90%.
: 8 Shock of earthquake:less than 8 magnitude.
In the application of no fire explosion heavy dust chemical
corrosion and violent vibration etc.
: Note: Special condition and requirement, please consult with
3
the manufacturer.
Main Characteristics
XGN -12 XGN -12 series RMU feature
; Extremely reduced overall dimensions.
; Switchboards can be wall-type.
; Controls and connections are on the front of the
; switchgear.
Easy inspection and fast maintenance.
; Many different simple solutions are available to ex-
; tend existing switchboards.
; Careful selection of materials.
; Isolators and switch disconnectors in drawer ver-
; sion to make replacement easier and faster (modular)
; Small dimensions.
; Nearly no maintenance.
; Conventional mode of operation.
Easy cable connection.
High electrical and mechanical reserves.
1Safety
XGN -12 : On the XGN -12 series RMU the safety of operators is
guaranteed by:
IP4X IP2X; Degree of protection(IP4X exterior and IP2X interior)
; Internal arc-proof structure (channelling on back).
; Mechanical interlocks that prevent incorrect operat-
ing sequence.
; The load switch can be closed only when the earthing
; switch is open and the door closed.
( ); The earthing switch can be closed only if the load
; switch is open.
SF6 ; Continuity of the metal strucure(with earthing connection)
; Key locks or arrangement for locks (optional)
SF6 earthing switch with making capacity
Voltage control by means of lamps with capacity
dividers.
4
Technical Data of switchgear
Load-switch switch-fuse C.B panel
Item Unit
combinations panel
Rated voltage kV 12 12 12
Rated frequency Hz 50 50 50
Main busbar A 1250 1250 1250
Rated current
Main circuit A 630 200 1250
Rated short circuit closed current A 630
Rated cable charging current kA 35
Rated making current (peak) kA 50 80 50(63)
FLN -12
X G N - 1 2 Series SF6 Insulated Ring-main Unit
F L N - 1 2Series SF6 Insulated Load-switchXGN -
F L N -
XGN -12 SF6 XGN -12 Series SF6 Insulated Ring-main unit,acombination of foreign ad-
vanced technology and domestic power-supply demand, is designed and
manufactured by Jiangsu Changjiang Electric Co. Ltd. Certified by integrated
inspection and long-term trial operation, its performance has detinitely entirely
IEC298 GB3906 3~35kV reached standards of IEC298 AC Enclosed Metal Switching Equipment
and GB3906 3~35 kV AC Metal Enclosed Switchgear Equipment , and its
IP4X protective grade is up to the standard of IP4X .Characterized by its small size,
easy handling and convenient maintenance, the Ring-type Network Switchgear
has become a new unember of Middle-voltage products widely used in
construction of urban and rural electric network.1
-12
Type and Designation
2
-12
Operational Conditions
3
Main Characteristics
4
Technical Data of switchgear
5
Outline Dimensions
6
Construction
7
FLN -12 SF6
FLN -12 Series SF6 Insulated Load-switch
8
Primary schemes
9
Installation1
Type and Designation
X G N -12
box-type Rated short-time withstand current
Fixed
Rated current
Indoor
No. of Design (kV) Rated voltage
2
Operational Conditions
: +40 -25 Ambient temperature:+40 to -25 .
: 1000m Maximum site altitude:1000m max.
: 95 ; Relative humidity:daily average less than 95%,
90 monthly average less than 90%.
: 8 Shock of earthquake:less than 8 magnitude.
In the application of no fire explosion heavy dust chemical
corrosion and violent vibration etc.
: Note: Special condition and requirement, please consult with
3
the manufacturer.
Main Characteristics
XGN -12 XGN -12 series RMU feature
; Extremely reduced overall dimensions.
; Switchboards can be wall-type.
; Controls and connections are on the front of the
; switchgear.
Easy inspection and fast maintenance.
; Many different simple solutions are available to ex-
; tend existing switchboards.
; Careful selection of materials.
; Isolators and switch disconnectors in drawer ver-
; sion to make replacement easier and faster (modular)
; Small dimensions.
; Nearly no maintenance.
; Conventional mode of operation.
Easy cable connection.
High electrical and mechanical reserves.
1Safety
XGN -12 : On the XGN -12 series RMU the safety of operators is
guaranteed by:
IP4X IP2X; Degree of protection(IP4X exterior and IP2X interior)
; Internal arc-proof structure (channelling on back).
; Mechanical interlocks that prevent incorrect operat-
ing sequence.
; The load switch can be closed only when the earthing
; switch is open and the door closed.
( ); The earthing switch can be closed only if the load
; switch is open.
SF6 ; Continuity of the metal strucure(with earthing connection)
; Key locks or arrangement for locks (optional)
SF6 earthing switch with making capacity
Voltage control by means of lamps with capacity
dividers.
4
Technical Data of switchgear
Load-switch switch-fuse C.B panel
Item Unit
combinations panel
Rated voltage kV 12 12 12
Rated frequency Hz 50 50 50
Main busbar A 1250 1250 1250
Rated current
Main circuit A 630 200 1250
Rated short circuit closed current A 630
Rated cable charging current kA 35
Rated making current (peak) kA 50 80 50(63)
您好,XGN口-12系列交流高壓SF6環(huán)網(wǎng)開關設備是一種專門用于電力系統(tǒng)的高壓電氣設備。它屬于GIS(Gas Insulated Switchgear)即氣體絕緣開關柜的一種,"XGN"是國際通用的設備型號標識。這種設備的主要特點是:
1. **高壓交流**:它適用于交流電壓在12kV或更高級別的電力網(wǎng)絡中。
2. **SF6氣體絕緣**:使用六氟化硫(SF6)作為絕緣介質(zhì),這是一種高效、安全且絕緣性能優(yōu)異的氣體,能夠保證設備在高電壓下運行時的安全性。
3. **環(huán)網(wǎng)設計**:意味著它可以構成一個閉合的電力網(wǎng)絡,便于線路的切換和擴展,提高了供電的靈活性和可靠性。
4. **開關設備**:包含了斷路器、隔離開關、接地開關等功能單元,可以進行開斷、隔離和保護電力線路。
如果您有關于這個設備的操作、維護、選購或者其他具體問題,請隨時告訴我,我會盡力提供幫助。
XGN口-12系列交流高壓SF6環(huán)網(wǎng)開關設備的相關資源推薦
會員專享
開通會員
升級會員獲取海量資源免費下載
會員免費下載
5D幣 購買
上傳資源賺收益
格式:pdf
瀏覽:341
收藏:0
瀏覽:341??|??
收藏:0
上傳時間:2011-01-10
大?。?span style="color: #444444;" data-v-698f9846>7.1M

作者相關作品
排名
昵稱
瓦特值
熱門標簽